Opening Hour

Mon - Sun, 08:00 - 24:00

Call Us

+86-21-5838618

Treatment of Femoral Neck Fractures: Unipolar Versus ...

Treatment of Femoral Neck Fractures: Unipolar Versus ...

+

Unipolar Versus Bipolar Hemiarthroplasty 7 SUBJECTS AND METHODS ... Mean Harris hip score was better with the bipolar group. Lunceford Jr7 felt that the pain following hemiarthroplasty should not be the reason for condemning the procedure. He listed .

Aesculap Orthopaedics BiPOLAR CUP

Aesculap Orthopaedics BiPOLAR CUP

+

BiPOLAR CUP is determined using corresponding trial implants. The necessary neck length of the AESCULAP hip endoprosthesis head is also determined using trial implants before the BiPOLAR CUP is connected to the modular hip endoprosthesis head using the locking ring. The special AESCULAP instrument ND 930 R should be used to insert the locking ...

Spontaneous reduction of dissociated components of modular ...

Spontaneous reduction of dissociated components of modular ...

+

Abstract. Three years after modular bipolar hemiarthroplasty for avascular necrosis of the femoral head, a patient's modular head and neck components became dissociated following a .

Biomed Orthopedics | Product

Biomed Orthopedics | Product

+

Modular Bipolar/Total Hip Replacement (THR) Modular Femoral Stem Modular Head

BIPOLAR CUP

BIPOLAR CUP

+

MULTIPOLAR BIPOLAR CUP ASSEMBLY Seat the femoral head securely in the polyethylene liner. The inner split ring will expand to allow ... MULTIPOLAR BIPOLAR CUP SIZING CHART BIPOLAR UHMWPE LINER ID (Femoral Head Size) METAL SHELL 22mm 26mm 28mm 32mm OD (mm) . No. . No. . No. . No. . No.

Modular Bipolar Hip, Orthopedic Equipment Supplies ...

Modular Bipolar Hip, Orthopedic Equipment Supplies ...

+

Modular Bipolar Hip Get Latest Price The Adler Endofit femoral hip stem design is a dual tapered, highly polished stem based on a design that has proven itself clinically over more than three decades of highly successful polished dualtapered Endofit stem is based on the highly successful loaded taper principle precise control of ...

Bipolar Hip Prosthesis Manufacturers, Suppliers Dealers

Bipolar Hip Prosthesis Manufacturers, Suppliers Dealers

+

Bipolar Hip Prosthesis To explore untapped opportunities in dome... To explore untapped opportunities in domestic and international market, we are engaged as manufacturer, supplier and exporter of Bipolar Hip Prosthesis in Delhi, Delhi, India. Our offered products are manufactured according to market needs and industry standards.

Modular Bipolar cup Manufacturer GPC Medical

Modular Bipolar cup Manufacturer GPC Medical

+

GPC Medical Modular Bipolar cup manufacturer, supplier and exporter from India. We offer best quality Modular Bipolar cup at lowest price. Browse Modular Bipolar cup catalogue online get a quote instantly! ... Bipolar Hip Prosthesis (Non Fenestrated) Sterile Model No: BHPN37 View Detail; Thompson Hip Prostheses Sterile/Non Sterile Model ...

Solar Hip Modular Bipolar System

Solar Hip Modular Bipolar System

+

The Solar Hip Modular Bipolar System is designed to offer comprehensive solution in neck of femur fractures in elderly patients. The Solar Hip Modular assembly comprises of cemented Orion Stem, Jupiter Head, Saturn Bipolar Cup with UHMWPE Cup liner.

EARLY CLINICAL RESULTS OF MODULAR BIPOLAR .

EARLY CLINICAL RESULTS OF MODULAR BIPOLAR .

+

Hemi or total hip arthroplasty is an accepted treatment of fracture neck of femur in the elderly. With the introduction of modular hemiarthroplasty whether unipolar or bipolar the neck length can be adjusted with regards to tension of abductors and leg length and further it can more easily be converted to Total Hip Replacement.

(PDF) Early Complications Following Cemented Modular Hip ...

(PDF) Early Complications Following Cemented Modular Hip ...

+

Early Complications Following Cemented Modular Hip Hemiarthroplasty. ... Early Complications Following Cemented Modular Hip ... (bipolar prosthesis), ...

Modular Bipolar CUP

Modular Bipolar CUP

+

Modular Bipolar CUP Moduloc Bipolar Cups are an alternative to total hip arthroplasty, particularly in the treatment of displaced femoral neck fractures in elderly patients.

Hip Fracture BrocHure CORAIL PINNACLE

Hip Fracture BrocHure CORAIL PINNACLE

+

Hip Fracture BrocHure. 2 DePuy Synthes Hi ractur rochure. ... approximately 5% of all hip fractures occur in the young. the major cause of hip fractures in the young ... SelfCentering Bipolar Heads Modular Cathcart Unipolar Heads orderiNg iNForMatioN 41 mm 42 mm

CASE REPORT Disassociation at the head trunnion interface ...

CASE REPORT Disassociation at the head trunnion interface ...

+

an unseen complication of modular hip hemiarthroplasty ... practice tariff, modern modular hip prostheses are used. These have replaced traditional monoblock ... However, the increased modularity of the bipolar head may make impaction more dif´Čücult and allow excessive rotation at the modular interfaces, which may

Hip Prosthesis Austin Moore Prosthesis Manufacturer from ...

Hip Prosthesis Austin Moore Prosthesis Manufacturer from ...

+

Hip Prosthesis We are a leading Manufacturer of austin moore prosthesis, total hip prosthesis, modular bipolar prosthesis and bipolar hip prosthesis fixed from Sonipat, India.

Modular Bipolar Cup Manufacturer,Supplier,Exporter,Buy ...

Modular Bipolar Cup Manufacturer,Supplier,Exporter,Buy ...

+

Offered Modular Bipolar Cups aid in hip arthroplasty of patients, who are suffering with rheumatoid arthritis, primary osteoarthritis and avascular necrosis of femoral head. Cement was utilized in femur whenever there was noticeable osteoporosis or wide medullary channel.